1175×575 Cleanroom Fan Filter Unit with HEPA/ULPA Filter SKU602
SKU :
SKESD SKU602 is a 1175×575×300mm cleanroom fan filter unit designed for modular cleanrooms, ceiling-mounted cleanroom systems, laboratories, electronics workshops, pharmaceutical areas and controlled environments. The unit integrates a fan, primary filter, HEPA or ULPA filter and speed control system to deliver filtered airflow for particle control.
This model supports H13, H14 and ULPA filter options, 0.36–0.6m/s three-speed adjustable air velocity, EC/AC/ECM motor options, 110V/220V power supply and low-noise operation at 48–52dB. Plastic impeller and aluminum impeller options are available, with galvanized sheet or stainless steel housing according to project requirements.
| Impeller type | Unit Price (Ex-work GZ) | QTY(pcs) |
|---|---|---|
| Plastic impeller | $129 /pc | 50 |
| Aluminum impeller | $140 /pc | 50 |
Specification and Data
| Product Name | Fan Filter Unit / FFU |
|---|---|
| Material | Galvanized sheet / stainless steel |
| Dimension | 1175×575×300mm |
| Material Thickness | 0.8 mm or customized |
| Air Velocity | 0.36–0.6m/s, three-speed adjustable |
| Filter Efficiency | H13: 99.99% @ 0.3μm; H14: 99.999% @ 0.3μm; ULPA option |
| HEPA Size | 1170×570×69mm |
| Impeller | Plastic impeller / aluminum impeller |
| Fan Motor | EC / AC / ECM |
| Power Supply | AC/DC 110V or 220V, 50/60Hz |
| Extra Primary Filter | Filter large particles |
| Pressure | 97Pa / 10mmAq |
| Noise | 48-52dB |
| Body Weight | 25Kg |
SKU602 is designed for cleanroom ceiling systems and modular cleanroom layouts requiring a larger 1175×575mm FFU footprint. Compared with smaller 575×575mm FFU models, SKU602 can be selected when broader filtered airflow coverage is required within a cleanroom grid, clean booth, laboratory or controlled production area.
SKU602 can be supplied with plastic or aluminum impeller options. Plastic impeller configuration is more cost-effective for standard projects, while aluminum impeller configuration can be selected when customers prefer a more durable impeller option. Final selection should be confirmed according to airflow requirement, operating environment and project budget.
SKU602 supports three-speed adjustable air velocity from 0.36 to 0.6m/s, allowing users to balance airflow demand, cleanliness requirements, noise and energy consumption. The listed noise level is 48–52dB, making it suitable for cleanroom and laboratory areas where stable airflow and controlled operating noise are required.
Galvanized sheet housing is suitable for general cleanroom and industrial clean air applications. Stainless steel housing can be selected for laboratories, pharmaceutical areas, food and beverage controlled environments or projects requiring easier cleaning and improved corrosion resistance.
HEPA H13, H14 and ULPA Filter Options
| Filter Option | Listed Efficiency | Suggested Use |
|---|---|---|
| H13 HEPA | 99.99% @ 0.3μm | general cleanrooms, labs, electronics assembly |
| H14 HEPA | 99.999% @ 0.3μm | higher cleanliness requirements, pharmaceutical or semiconductor areas |
| ULPA | available option | critical clean zones, microelectronics and precision applications |
Note: The final cleanroom class depends on room design, FFU coverage, airflow balance, leakage control, particle load, installation quality and validation testing.
Applications of SKU602 Fan Filter Unit
- Modular cleanrooms
- Clean booths
- Ceiling-mounted cleanroom systems
- Electronics assembly workshops
- PCB and SMT production areas
- Semiconductor laboratories
- Pharmaceutical cleanrooms
- Food and beverage controlled areas
- Medical device assembly
- Life science laboratories
- Local clean zones
- Clean benches and laminar flow work areas

FAQ
Q1: What is SKU602 fan filter unit used for?
SKU602 is used for cleanrooms, laboratories, electronics workshops, food and beverage controlled environments, life science facilities and microelectronics areas that require filtered airflow.
Q2: What is the size of SKU602 FFU?
SKU602 has an overall dimension of 1175×575×300mm and a HEPA filter size of 1170×570×69mm.
Q3: What filter options are available?
The listed filter options include H13, H14 and ULPA. The page lists H13 at 99.99% @ 0.3μm and H14 at 99.999% @ 0.3μm.
Q4: What air velocity is available?
The listed air velocity is 0.36–0.6m/s with three-speed adjustable operation.
Q5: What is the noise level of SKU602?
The listed noise level is 48–52dB.
Q6: Does one SKU602 FFU guarantee a specific ISO cleanroom class?
No. A single FFU does not independently guarantee a specific cleanroom class. The final class depends on cleanroom design, FFU coverage, airflow, leakage control, particle load, installation quality and validation testing.
Send us your cleanroom size, required airflow, filter grade, voltage, housing material, impeller type and quantity for a quote.
For more options, visit our main section for FFU(Fan Filter Unit).
Order Fan Filter Units
To order the fan filter unites, please click email info@skesd.com. We can provide ODM/OEM services according to your requirements.
In addition to Fan filter units, we also offer a variety of other ionizing products including air showers, ionizing air blowers,and cleanroom pass boxes.